|
|
 |
 |
 |
Microlite BackupEDGE
Technical Support |
|
|
Title
|
|
I've installed a Rev drive in my server and I'm experiencing read/write errors.
|
|
Keywords
|
|
IOMEGA rev 35GB 70GB BackupEDGE error 4 failed
|
|
Product Release(s)
|
|
02.02.00 build 2 and earlier
|
|
Operating System(s)
|
All Supported
|
|
Problem Description
|
|
I've been getting write or read errors on my 35 or 70 GB REV drive.
|
|
Cause
|
|
Although a write/read error is commonly caused by bad media, it can also be a
result of outdated firmware on the drive.
|
|
Solution
|
|
It is recommended your REV drive firmware be up to date. The current revision for the 35 GB drive is 23.B and the revision for the 70 GB drive is P094.
The firmware updates are available at www.iomega.com
|
|
Notes
|
|
|
Get a printer-friendly version of this document
|
|
|
Last Modified Tuesday, September 02, 2008
Site Content Copyright ©1999-2008 by Microlite Corporation. All Rights Reserved |
|
|