Microlite BackupEDGE
Technical Support |
|
|
Title
|
|
I set & exported the environment variable VOL_SWITCH_CMD for my autochanging tape drive.
|
|
Keywords
|
|
edge 4mm Autochanger tape drives edge.cfg VOL_SWITCH_CMD
|
|
Product Release(s)
|
|
01.00.0x 01.01.0x
|
|
Problem Description
|
|
I set & exported the environment variable VOL_SWITCH_CMD for my
autochanging tape drive. The command issued works from the command
line but not from edgemenu.
|
|
Cause
|
|
This is caused by an error in the documentation & an error in the
environment variable definition in /etc/default/edge.cfg.
|
|
Solution
|
|
The variable is incorrectly identified in /etc/default/edge.cfg as
VOL_SWITCH_CMD. A search of the edge binary shows it should have
been SWITCH_VOL_CMD. Make the correction in /etc/default/edge.cfg,
as well as in your manual (page 106).
This will be corrected in later releases of BackupEDGE &
in later printings of the manual.
|
Get a printer-friendly version of this document
|
|
|
Last Modified Tuesday, September 02, 2008
Site Content Copyright ©1999-2008 by Microlite Corporation. All Rights Reserved |
|
|